本资料为湖南综合楼机电安装工程方案一、项目概况位于 XX大河西湘江新区, xx 路和 XX路交叉口西南角,由一个 1800座的大剧场、一个 500 座的小剧场 ( 多功能厅) 、一个当代艺术馆以及为整个项目配套的零售、餐厅和咖啡厅,以及为以上公共设施配套的设备用房、剧务用房、演出用房、行政用房、停车场等组成。总建筑面积 125936平方米二、消防系统工程概况本工程消防电系统共设计有 : 消防报警及联动控制系统、气体灭火系统、消防电源监控系统、消防电源巡检系统、应急照明和智能疏散系统、火灾应急广播系统等系统。目 录一、工程概况 ····································································· 1二、编制依据 ····································································· 1三、消防系统工程概况 ························································· 2四、组织架构及岗位职责 ······················································ 3五、施工总则 ····································································· 8六、消防报警及联动系统 ······················································ 8七、气体灭火系统 ······························································ 11八.应急照明和智能疏散系统 · ················································ 17九.消防设备电源监控系统 · ··················································· 19十、施工前期准备及施工工艺 · ·············································· 21十一 施工技术要求 · ··························································· 25十二 系统调试方案 · ··························································· 32湖南综合楼机电安装工程消防报警及联动系统选择阀的安装消防设备电源监控系统功能布管、布线
本资料为湖南综合楼机电安装工程方案,本工程消防电系统共设计有 : 消防报警及联动控制系统、气体灭火系统、消防电源监控系统、消防电源巡检系统、应急照明和智能疏散系统、火灾应急广播系统等系统。
本资料为湖南综合楼机电安装工程方案,本工程消防电系统共设计有 : 消防报警及联动控制系统、气体灭火系统、消防电源监控系统、消防电源巡检系统、应急照明和智能疏散系统、火灾应急广播系统等系统。